Goodwe protocol integration

ZenovaConnect integrates Goodwe devices via 固德威国内 OpenAPI 1.0, normalizes fields, and pushes to your channel.

✓ Production

Integration details

API source
固德威国内 OpenAPI 1.0
Category
逆变器
Auth method
api-key
Data resolution
5min
Downlink control
No
Applied at
2024-04
Production since
2024-Q4

户用 + 商用全覆盖,下行控制规划中

Production observations

SEMS Portal domestic OpenAPI v1.0.1.2. Account + password exchanged for a 2-hour token; strict tenant isolation (each customer account sees only its own plants). No 5-minute realtime endpoint — finest historical granularity is 15 minutes. Customers needing realtime monitoring need to align expectations upfront. Timezone is per-plant dynamic — must be looked up via device metadata second query.

Field mapping

Vendor fieldBaseData fieldNote
powerstation_idPlantIdPlant ID
snInverterSNDevice SN
edayEDaykWh
etotalETotalkWh
pacPowerACOutputActiveW (note: W, not kW)
tempperatureTemperatureNote vendor typo; Celsius
facFrqACHz
vac1, vac2, vac3UAC1, UAC2, UAC3V · three-phase
iac1, iac2, iac3IAC1, IAC2, IAC3A · three-phase

Integration gotchas

  • No 5-min endpoint — finest realtime is 15 min; manage realtime-monitoring expectations upfront
  • Timezone is per-plant dynamic — requires a metadata lookup
  • pac unit is W not kW — easy to confuse with other vendors
  • Vendor field 'tempperature' has a typo — pin the mapping in the adapter layer

✓ INTEGRATED IN ZENOVACONNECT

Production integration since 2024-Q4 · source 固德威国内 OpenAPI 1.0

Field observations

We documented 9 vendor integrations in detail. This brand is covered.

Read the article

Ready to integrate Goodwe?

Onboard once, then field normalization, API revision tracking, and alarm semantics stay handled.